CHARLOTTE, NC
CHARLOTTE CONVENTION CENTER
3 devices · 501 S. COLLEGE ST., CHARLOTTE, NC, 28202
Work history
Who worked this, and when · ProInspection
Last inspected Aug 19, 2026 · status 1
Inspection history over time · ProMarket status
Warranty window and signs of trouble · ProDevices
- Freight · installed 1995 · ESCO · HYDRAULIC · 7,000 lb · 75 fpm · 4 stops · last inspected Jun 2, 2026 · 2
- Freight · installed 2007 · SCHINDLER · TRACTION · 8,000 lb · 200 fpm · 2 stops · last inspected Feb 17, 2026 · 1
- Escalator · installed 2010 · SCHINDLER · 9,000 lb · 100 fpm · 2 stops · last inspected Aug 19, 2026 · 1